TLX Silver

Multifoil Vapour Barrier - The UK's Leading Multifoil Insulation

THE UK’S TRUSTED MULTIFOIL INSULATION

TLX Silver is the UK’s leading multifoil insulation product, used in thousands of properties nationwide. Whether for new builds, loft conversions, extensions, or barn conversions, TLX Silver is the preferred choice.

TLX multifoil insulation has undergone independent testing by fully accredited laboratories, meeting the latest British and European standards. It was the first foil insulation to receive the prestigious BBA Certificate of Agrément.

UK's leading multifoil insulation - used in thousands of properties nationwide
BBA Certificate of Agrément - first foil insulation to receive this prestigious certification
Independently tested by fully accredited laboratories - meets latest British & European standards
Radiant barrier - reflects infra-red radiation back into the property
Vapour barrier - prevents interstitial condensation in roofs and walls
Airtight membrane - reduces draughts and prevents warm air escaping
Thermal brake - limits heat flow through timber rafters and studs
Reduces heat loss via all three means: radiation, conduction and convection
Free technical support - U-value calculations, condensation risk analysis, building control assistance

Thermal insulation

TLX Silver is a radiant barrier. The reflective surfaces on the outside and inner layers of TLX Silver are very effective at both reflecting infra-red radiation back into the house, and also in preventing the house from radiating energy out into the environment. Similarly in summer, TLX Silver prevents overheating by limiting the amount of solar radiation that gets into the house.

The wadding layers inside TLX Silver prevent conduction through the material by trapping air between the fibres. The inner films are spaced to prevent convection currents from forming within the body of TLX Silver.

TLX Silver reduces heat loss via all three means of heat transfer – radiation, conduction and convection.

Vapour control

TLX Silver is a vapour barrier. When installed on the warm side of a roof or wall structure it prevents water vapour from the house penetrating into the roof or wall where it might find a cold surface on which to condense.

Airtightness

TLX Silver is airtight, and by wrapping around a roof or wall, including junctions with other parts of the building such as windows or doors, it makes the whole building envelope more airtight. This reduces unpleasant cold draughts, and prevents the escape of warm air from the house.

Thermal bridging

TLX Silver fits across timber members such as rafters or wall studs, acting as a thermal brake to limit heat flow through the timber.

U-values

The temperature inside most houses is maintained at a comfortable level of around 20°C in living areas and 17°C in bedrooms. In the UK, the outside temperature is generally lower than this, especially in the winter. Heat flows from the warmer interior of the house, through the fabric of the building, to the outside. The U-value expresses the rate at which heat is lost through a part of the house – such as roof, walls or windows. The U-value is expressed in units of Watts of power for every square metre of roof and for every degree temperature difference between the inside and the outside, or W/m².K.

Part L1B 2010 requires a renovated roof to have a U-value of 0.18 W/m².K. If the roof has an area of 70 square metres, and the temperatures inside and outside are 17 and 5°C, then the rate of heat loss through that roof is:

0.18 x 70 x (17 – 5) = 151 Watts

The U-value of a roof is calculated by breaking the roof structure down into separate layers – such as plasterboard, insulation, rafters and underlay. The thermal resistance of each component is added together. Any materials of high thermal conductivity, such as timber rafters, form a cold bridge through the structure, and must be accounted for in the calculation, as must fixings and any poorly fitted insulation. The inverse of the total thermal resistance of the roof, corrected for cold bridging and other factors such as fixings, gives the U-value for that roof structure. Examples of U-value calculations are shown in the TLX Silver solutions.

All TLX Silver U-value calculations are carried out according to BS EN ISO 6946.

Condensation risk

In general, the water vapour pressure inside the house is greater than the vapour pressure outside. As well as heat trying to escape the building, so too water vapour tries to escape through the building fabric to the outside. The main mechanism by which water vapour is eliminated should be through adequate ventilation. However, vapour will also try to diffuse through the walls and roof.

Water vapour coming into contact with a cold surface will condense, as can be seen on the inside of windows after a cold night. Condensation within the structure of the roof, known as interstitial condensation, can have adverse effects. Excess water can lead to mould growth, or staining of interior plaster or timbers. To prevent interstitial condensation, the roof structure must be built such that materials with higher vapour resistance are positioned to the inside of the building. This prevents water vapour from penetrating the wall structure to a cold part of the roof. TLX Silver is a vapour barrier, and has a very high vapour resistance. When it is located on the inside of the roof it prevents water vapour from getting into the roof structure, eliminating the risk of interstitial condensation.

TLX Silver standard solutions contain an analysis of the risk of interstitial condensation, calculated to BS EN ISO 13788, which show no risk of harmful condensation. The calculation assesses diffusion of water vapour through the materials of construction, but not water vapour in moist air that leaks into the roof structure. It is essential that the ceiling is as well sealed as possible to prevent movement of moist air from carrying water vapour into the roof.

Cold Roof Area - Insulation Above Ceiling0.16Part L1B 2010 requirement. TLX Silver as vapour barrier with supplementary insulation.
Pitched Roof - Sloping Ceiling0.18Part L1B 2010 requirement. Calculation per BS EN ISO 6946.
Flat Roof Dormer0.18Part L1B requirement for flat roof dormer constructions.
Dwarf Wall0.28Part L1B requirement for dwarf walls in loft conversions.
Dormer Cheek0.28Part L1B requirement for dormer cheek constructions.

Loft conversions and extensions

These are covered by Approved Document Part L1B 2010. This states that in England and Wales each element must be insulated to achieve a level of heat loss, or U-value, as shown in the table.

Element U-value required W/m².K
Cold roof area, insulation above ceiling 0.16
Dwarf wall 0.28
Pitched roof, sloping ceiling 0.18
Flat roof dormer 0.18
Dormer cheek 0.28

Generally, Local Authority Building Control will require these U-values to be achieved. Similar values operate in Northern Ireland and Scotland.

 

Re-roofing

When a house is to be re-roofed or at least 50 percent of the roof area is to be repaired a requirement is triggered in Part L1B to upgrade the thermal performance to the levels above.

It may, however not be possible to deliver a thermal performance upgrade to Building Regulation standards in all instances – perhaps the roofline cannot be raised since the house is either semi-detached or terraced, or a historic building whose appearance cannot be altered – and there may be a need for the roof insulation to remain breathable. In these circumstances, it may be permissible to reach a lesser U-value, but these must be agreed with the Local Authority Building Control.

 

New build

New build houses are covered by Approved Document L1A and the Code for Sustainable Homes. This approach uses a SAP process to calculate the carbon emissions of the whole house.

From 2010, private sector houses must meet Code level 3 and public sector houses Code level 4. In 2013 this changes, and private sector houses must meet Code level 4 and public sector houses Code level 6. From 2016 all new houses must reach Code level 6. The U-values of each element of the building are flexible, provided the whole house meets the standard, but the U-values need to comply will be typically:

Code level
Pitched roof Wall Air permeability Thermal bridging
3 0.18 0.24 Reduced Reduced
4 0.16 0.20 Reduced Reduced
6 0.16 0.16 Maximum possible reduction Maximum reduction

TLX Silver helps to meet the required U-values when used in conjunction with other insulation such as mineral fibre or rigid board. TLX Silver is particularly effective at reducing air permeability by sealing across timber studs and rafters and by wrapping around junctions.

 

C2 – resistance to moisture

Approved Document C2 Resistance to Moisture (6.10) states that a roof will resist damage from interstitial condensation if it is constructed in accordance with BS5250. A condensation risk analysis should be carried out on any proposed renovated roof structure. In addition, excessive moisture transport into the roof through moist air movement must be avoided by sealing junctions, gaps and service penetrations.

 

Regulation 7

Regulation 7 Materials and Workmanship states that building work should be carried out with adequate and proper materials. To ensure a material is suitable, it should comply with British or other national standards, be covered by a certificate issued by an ETA issuing body (such as BBA or DIBt), have a CE mark, or be certified by a UKAS accredited body.


hotline_logo

We provide free technical support from our head office in Bolton with a team of operatives based across the UK.

Whether you want:

  • To know what building regulations apply.
  • To know how TLX Silver should be fitted.
  • U-value and condensation calculations.
  • Access to CAD drawings.
  • Information on energy payback calculations.
  • Or just someone to talk to building control.

 Our technical team is available on 01204 674730 or email technical@tlxinsulation.co.uk

How to Install TLX Silver

Watch the installation video or download the installation guide PDF.

Abutments

040_Abutment Detail – TLX Silver (counter battened).pdf
041_Abutment Detail – TLX Silver.pdf

Chimney

053_Chimney Stack Detail – TLX Silver (counter battened).pdf
054_Chimney Stack Detail – TLX Silver.pdf

Eaves

003_Eaves Detail – TLX Silver (counter battened).pdf
006_Eaves Detail – TLX Silver (installed underside of rafters).pdf

Gable & verge

021_Gable Detail – TLX Silver.pdf
027_Verge Detail – TLX Silver (counter battened).pdf

Parapet gutter

059_Parapet Gutter Detail – TLX Silver (counter battened).pdf
060_Parapet Gutter Detail – TLX Silver.pdf

Purlin

018_Purlin Detail_TLX Silver.pdf

Recessed Lighting

019_Downlighter Detail_TLX Silver.pdf

Reveal

012_Reveal Detail_TLX Silver.pdf
012a_Jamb Detail_TLX Silver.pdf

Ridge

020_Ridge Detail – TLX Silver.pdf
022_Ridge Detail – TLX Silver (counter battened).pdf
047_Mono Pitch Detail – TLX Silver (counter battened).pdf
048_Mono Pitch Detail – TLX Silver.pdf

Rooflights

017_Rooflight Detail – TLX Silver (counter battenend).pdf

Timber frame – floor junction

063_Wall to Floor Detaill_TLX Silver (timber frame).pdf

Timber frame – intermediate floors

042_Intermediate Floor Detail_TLX Silver.pdf

Timber frame – roof junction

061_Roof Junction Detail (cold roof)_TLX Silver (timber frame).pdf
062_Roof Junction Detail (warm roof)_TLX Silver (timber frame).pdf

Valley

011_Valley Detail – TLX Silver (counter battened).pdf

View the full LABC Approved Solutions Guide.

Can’t find what you are looking for? Contact us.

These days there are few guarantees that don’t come with a page full of small print so we think you will like our product assurance pledge.

Whether you are a builder. roofer or homeowner we keep our promise simple and provide you with peace of mind where you need it most.

Reassurance for roofers

As a roofer you want to know your product choice is fit for purpose and will deliver to required Building Standards.

With TLX Gold, TLX Silver and TLX UV membranes you can tick that box. They are all certified by the British Board of Agrément to have been manufactured to comply with UK Building Regulations.

These tests include accelerated ageing to replicate the use of these products over the life of the roof.

This means is that that not only do we deliver on product performance, but we also guarantee our u-value and condensation risk calculations.

TLX Batsafe

TLX Batsafe is built on the TLX UV membrane platform and therefore carries the same guarantee as our other products.

Reassurance for householders

Supported by the building Industry, retail and consumer protection organisations, TrustMark has the largest database of accredited tradesmen in the country and as a member we support you by only recommending reliable tradesmen and

Regulations demonstrating that we require high standards of Installation from them.

Our products are also backed by the NFRC (National Federation of Roofing Contractors) and we only recommend the installation of our products by NFRC and TrustMark approved roofers. NFRC and TrustMark approved roofers offer a warranty on thejir work which will also honour a roofers guarantee in the event that they cease to trade.

Our product assurance pledge which includes our U-value and condensation risk calculations will give you long term comfort and peace of mind.

Downloads

BBA Certificate – Pitched Roof

BBA Certificate – Walls

TLX Silver Declaration of Conformity

CAD Drawings

Technical CAD drawings for TLX Silver installation details.

    • 040_Abutment Detail - TLX Silver (counter battened)
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/040_Abutment-Detail-TLX-Silver-counter-battened-1.pdf
    • 041_Abutment Detail - TLX Silver
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/041_Abutment-Detail-TLX-Silver.pdf
    • 053_Chimney Stack Detail - TLX Silver (counter battened)
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/053_Chimney-Stack-Detail-TLX-Silver-counter-battened-1.pdf
    • 054_Chimney Stack Detail - TLX Silver
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/054_Chimney-Stack-Detail-TLX-Silver.pdf
    • 003_Eaves Detail - TLX Silver (counter battened)
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/003_Eaves-Detail-TLX-Silver-counter-battened-1.pdf
    • 006_Eaves Detail - TLX Silver (installed underside of rafters)
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/021_Gable-Detail-TLX-Silver.pdf
    • 021_Gable Detail - TLX Silver
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/006_Eaves-Detail-TLX-Silver-installed-underside-of-rafters.pdf
    • 027_Verge Detail - TLX Silver (counter battened)
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/027_Verge-Detail-TLX-Silver-counter-battened.pdf
    • 059_Parapet Gutter Detail - TLX Silver (counter battened)
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/059_Parapet-Gutter-Detail-TLX-Silver-counter-battened-1.pdf
    • 060_Parapet Gutter Detail - TLX Silver
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/060_Parapet-Gutter-Detail-TLX-Silver.pdf
    • 018_Purlin Detail_TLX Silver
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/018_Purlin-Detail-TLX-Silver.pdf
    • 019_Downlighter Detail_TLX Silver
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/019_Downlighter-Detail_TLX-Silver.pdf
    • 012_Reveal Detail_TLX Silver
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/012_Reveal-Detail_TLX-Silver.pdf
    • 012a_Jamb Detail_TLX Silver
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/012a_Jamb-Detail_TLX-Silver.pdf
    • 020_Ridge Detail - TLX Silver
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/020_Ridge-Detail-TLX-Silver.pdf
    • 022_Ridge Detail - TLX Silver (counter battened)
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/022_Ridge-Detail-TLX-Silver-counter-battened.pdf
    • 047_Mono Pitch Detail - TLX Silver (counter battened)
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/047_Mono-Pitch-Detail-TLX-Silver-counter-battened.pdf
    • 048_Mono Pitch Detail - TLX Silver
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/048_Mono-Pitch-Detail-TLX-Silver.pdf
    • 017_Rooflight Detail - TLX Silver (counter battened)
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/017_Rooflight-Detail-TLX-Silver-counter-battenend.pdf
    • 063_Wall to Floor Detail_TLX Silver (timber frame)
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/063_Wall-to-Floor-Detaill_TLX-Silver-timber-frame.pdf
    • 042_Intermediate Floor Detail_TLX Silver
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/042_Intermediate-Floor-Detail-TLX-Silver.pdf
    • 061_Roof Junction Detail (cold roof)_TLX Silver (timber frame)
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/061_Roof-Junction-Detail-cold-roof_TLX-Silver-timber-frame.pdf
    • 062_Roof Junction Detail (warm roof)_TLX Silver (timber frame)
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/062_Roof-Junction-Detail-warm-roof_TLX-Silver-timber-frame.pdf
    • 011_Valley Detail - TLX Silver (counter battened)
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/011_Valley-Detail-TLX-Silver-counter-battened.pdf
BBA Certificates
    • TLX Silver Pitched Roof BBA Certificate
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/TLX-SILVER-PITCHED-ROOF-BBA-CERTIFICATE.pdf
    • TLX Silver Walls BBA Certificate
    • , https://tlxinsulation.co.uk/wp-content/uploads/2026/07/TLX-SILVER-WALLS-BBA-CERTIFICATE.pdf
Product GuideTLX Insulation Product Guide, https://tlxinsulation.co.uk/wp-content/uploads/2026/07/TLX-insulation-product-guide-28.05.21.pdf
UKCA CertificateUKCA TLX Silver Certificate, https://tlxinsulation.co.uk/wp-content/uploads/2026/07/UKCA-UV-MEMBRANES-MAY-2026-1.pdf